Clean Environment
OLYMPIA KOGYO CO.,LTD.
Standard specifications
Air
High Temp.Air
Please consult about special specifications other than above-mentioned standard ones.
The specifications and the dimensions might be changed without an advanced notice for the improvement.
1. Duct Burner ass'y     2. Burner head    3. Fan casing    4. Air inlet   5. Fan motor 6. First cutoff valve    
7. Second cutoff valve    8. Pilot solenoid valve    9. Pilot governor    10. Gas pressure switch  11. Air pressure switch      12. Pilot cock    13. Main cock 14. Ignition transformer 15. Module control motor 16. Flame rod    17. Ignition bar    18. Relay terminal box 19. Inspection door 20.Sight window     21. Combination flange 
22. Base frame  23. Butterfly valve
                                  
Type  CD-50PW CD-100PW CD-200PW CD-300PW CD-400PW CD-500PW
 The maximum input   (kW) 58 116 233 350 465 580
Fuel consumption  LP gas  2.1 4.2 8.3 12.5 16.7 20.8
 13A gas 4.6 9.1 18.2 27.3 36.4 45.5
 6B gas 10 20 40 60 80 100
 6C gas 11.1 22.2 44.4 66.7 88.9 111.1
Supply pressure
(mmH
20)
 LP gas   280
 13A gas 200
 6B・6C gas 100
 Power source 200V 3φ
Capacity of motor(kW) 0.25 0.25 0.4 0.75 0.75 1.5
Combustion     method Pre-Mixing 
 Duct cross section (mm) 500×320 700×500 950×700 1100×900 1300×1000 1500×1100
Connecting pipe diameter(B)  LP gas   1/2 3/4 1 1-/1/4
 13A gas 1/2 3/4 1 1-/1/4 1-/1/2
 6B・6C gas 3/4 1 1-/1/2 2 2-/1/2 3
Turn down ratio 1:3 1:5 1:10
Type The maximum input(kW)
CD−50PW 58 1150 1020 875 650 130
CD−100PW 116 1150 1200 1055 850 130
CD−200PW 233 1150 1440 1275 1100 130
CD−300PW 350 1350 1650 1530 1250 130
CD−400PW 465 1450 1780 1690 1450 130
CD−500PW 580 1550 1895 1790 1650 130